Audix TR-40A
is a 6 mm pre-polarized condenser microphone used for test and measurement applications. The TR-40A is known for its linearity, accurate response, consistency, ease of use and affordability.
Characterized with a uniformly controlled omni-directional polar pattern, the TR-40A is designed to capture acoustical measurements for room analysis software programs, real time analyzers, and other sound control devices. With a wide frequency range of 20 Hz - 19 kHz, Audix TR-40A is an excellent tool for sound engineers and sound companies.
Requiring 9 - 52 Volts phantom power for operation, the TR-40A features a brass body with black e-coat finish and includes a mic clip and carrying pouch.
Item Includes
- Audix TR-40A Mic
- Mic clip (MC2)
- Carrying pouch (P1)
OPTIONAL ACCESSORIES - DCLIP - Tension-fit heavy duty nylon mic clip
- TRIPOD - Tripod mic stand
- SMT-25 - Shockmount system
- CBL-20 - 20?XLR-XLR mic cable
6 mm electret capsule
Linear response
Machined brass housing
Gold plated XLR
Low noise electronics
Measurement and Calibration
Because the TR-40 combines phase coherency with an extremely linear frequency response, it's perfect for use as a cost-effective measurement or calibration microphone for many of today's real-time room analyzers, automated equalizers, and software driven measurement programs.
Recording Techniques
Many recording engineers use the TR-40 as a creative tool to "naturally" blend the sound of an acoustic instrument with the "room". This provides a unique character and dimension to a recording which cannot be achieved any other way. Instruments such as piano, acoustic guitar, percussion, saxophone, and percussion all lend themselves to this creative process.
Live Sound
The TR-40 can be used successfully for a variety of applications from choir miking to overhead drum miking. The most interesting and original use of the TR-40 will be as a "room mic" providing a real time mix for performers equipped with in-ear monitor systems.
Broadcast Application
A series of TR-40's can be strategically placed over the audience in order to create the `live' feeling of the event.
| Transducer Type | Pre-Polarized Condenser |
| Frequency Response | 20 Hz - 19 kHz |
| Polar Pattern | Omni-directional |
| Output Impedance | 200 Ohms |
| Open Circuit Sensitivity | 17.9 mV / Pa |
| Equivalent Noise Level | 17 dB (A weighted) |
| Signal to Noise Ratio | 77 dB |
| Power Requirements | 9 - 52 Volts phantom |
| Maximum SPL | ≥128 dB |
| Cable/Connector | 3 pin gold plated male XLR connector |
| Polarity | Positive pressure on diaphragm produces positive voltage on pin 2 relative to pin 3 |
| Housing / Finish | Machined Brass / Black E-Coat |
| Weight | 141.74 g / 5 ounces |
| Length | 192.5 mm / 1.2 inches |
APPLICATIONS | Test and measurement Real time analyzers Room analysis software programs Ambient room miking Audience mics for ear monitors Recording |