Manley Variable Mu Compressor/Limiter

Manley Variable Mu Compressor/Limiter

$4,399.00
Out of stock
Qty:
SKU: MANLEYVARMU Category:

Manley Variable Mu is a favorite of producers and recording engineers – and one listen to what this device does for your sound will make you a believer, too! Anyone who has heard the classic Fairchild 670 Series limiters in action has an idea of this Variable Mu’s capabilities – but the sound is even sweeter with the Variable Mu. Its adjustable attack and release settings are optimized for mixing and mastering, but are flexible for most tracking situations. Sonically versatile and dependable for daily use, the Variable Mu is Manley’s best-selling device.

Features

MANLEY input & output transformers with nickel laminations in mu-metal cases with flat frequency response from 20Hz-25KHz

BALANCED INPUTS & OUTPUTS (600 Ohms)

Fully differential ALL-TUBE circuitry using one each 5670, 5751, 7044 or 5687, & 12AL5 per channel

Independently regulated B+ and Heater supplies

Hard-wire BYPASS switch

Stepped switch INPUT attenuator as of 10/2011. (older units use Silent dual-ganged potentiometer)

RECOVERY 5 steps: 0.2s, 0.4s, 0.6s, 4sec., 8sec.

Variable ATTACK: 25msec-70msec

Continuously variable THRESHOLD

LIMIT (4:1 to 20:1) or COMPRESS (1.5 to 1)

HP SC: High Pass Side Chain Filter -3dB @ 100Hz

Large ILLUMINATED Sifam METERS (older units before serial number MSLC61642 shipped before 12/2003 use: 26V 1.2W FESTOON LAMPS; Manley’s Part Number: VAR016B) Order spare bulbs using our parts order form. (newest units after serial number MSLC61642 shipped after 12/2003 use white LED lighting)

STEREO LINK SWITCH

Several units can be linked for Surround (custom order)

Specifications

Maximum gain: 35dB

Max. output: +30dBu (26Vrms) 26dB Headroom

<0.1% THD @ 1KHz Noise floor: -85dB typical

Power Consumption (120/240VAC): 80 watts

Unit is factory set for 100V, 120V or 220-240VAC operation for original destination country’s mains voltage.

Operating Mains Voltage changeable with power transformer changeover switch and fuse value change.

Mains Fuse Value for 100~120VAC operation: replace with 1.25A as of 10/2011

Mains Fuse Value for 220~240VAC operation: replace with 0.6A (600mA) as of 10/2011

Mains Fuse Type: MDA or MDL SLO-BLO Time delay 1 1/4″ x 1/4″

Mains Voltage Frequency: 50~60Hz

Dimensions: 19 x 3 1/2 x 10″ (chassis occupies 2u) Power transformer protrudes 3.5″ out the back of the chassis.

Shipping Weight: 23 lbs.